Town of Colchester, CT PUBLIC ACCESS PORTAL
Copyright ~ Point Software Inc. ~ All Rights Reserved

Guest Permit List

TIP: Table filtering occurs by entering any characters of column text in the white boxes. After selecting a row, choose an Icon to invoke action described.
Enter Search Text
Parcel Id  Owner  Location  Permit#  Permit Type  Issued  Fees  Status  Work Description   
   
   
   
03-03 0 039-003 JORDAN LAWRENCE D + CHERYL B 309 CHESTNUT HILL RD
25-133M
Mechanical 08/24/2025 256.00 Approved Remove existing 105 btu bioler with tankless coil and two zones of heat with New Yorker CL3-105 boiler with tankless coil and 2 zones of heat.I will repipe supply with sentry zone valves and spiral vent.I will repipe return piping with taco ECM circulator pump and purge. I will run new oil line from oil tank to Beckett burner with new Garber oil filter.I will run new vent pipe from bolier to chimney with draft regulator.I will wire boiler to code
4W-07 0 032-000 SWANBACK CARL E 66 DAVIDSON RD
Draft
Electrical   965.00 New Installing rooftop railed solar PV 15.58KW and 38 modules.
11-00 0 028-000 KEYSTONE SHOPPES LLC 179 LINWOOD AVE
Draft
Plumbing   73.00 Paid Final field hook up of an UL-300 approved factory installed wet chemical fire suppression system for the kitchen hood located at Chipotle.
16-00 0 069-000 SHARR REALTY LLC 119 SOUTH MAIN ST
Draft
Building   852.00 Payment Rcvd Description of Work Per Sign 1. FRONT ELEVATION (Sign #1): Replacement of existing illuminated sign from 52.21 SQ. FT. to 52.16 SQ. FT. 2. DRIVE-THRU PHARMACY ELEVATION (Sign #2): Installation of a new illuminated sign (17.65 SQ. FT.), no existing sign 3. DRIVE-THRU PHARMACY ELEVATION (Sign #3): Modification of existing non-illuminated letters. Replacing the existing 12 SQ. FT. with new sign to 17.65 SQ. FT. 4. PYLON ELEVATION (Sign #11): Replacement of existing pylon sign faces. It's a direct replacement of 47.29 SQ. FT. of illuminated signage. (like for like)
02-02 0 001-007 FONTANA ANTHONY + KELLY 78 RESERVOIR RD
Draft
Electrical   641.00 Payment Due Installation of 10.25kW DC PV roof mounted with 25 panels. Existing back-up generator installed. Satellite dish on AR-2 to be re-located by customer.
06-10 0 018-000 SHUMSKI LOVLEY DENISE + RAYMOND KEVIN J 31 HICKORY RD
Draft
Driveway   50.00 Paid Driveway Construction
06-06 0 030-000 CLEARY JOHN S + KATHRYN A 191 MILLER RD
25-132M
Mechanical 08/24/2025 782.00 Approved Removing 2 AC condensers and 2 air handlers. Installing 2 heat pump condensers and 2 new air handlers Condensers: 2 Bosch BOVA-36RTB-M20S 36,000 BTU heat pump condensers, using R454B refrigerant Air handlers: one 2 ton Bosch BIVA24RCBM20X air handler for the first floor and one Bosch BIVA36RCBM20X 36,000 BTU for the second floor
06-10 0 017-000 ALEXANDER PHILIP E + ELAINE M 27 HICKORY RD
Draft
Driveway   50.00 Paid Driveway Construction
03-00 0 001-522 HIDALGO MATTHEW + VEGA ESPANOL ZULANY 10 JORDAN LN
Draft
CO     New New Construction (Residential)
03-00 0 001-521 KENYON ROBERT 12 JORDAN LN
25-15CO
CO 08/22/2025   Approved New Construction (Residential)
06-16 0 018-000 ADKINS RALPH P + MARLENE E 155 BULL HILL RD
25-107CA
COC 08/20/2025   Closed Emergency boiler replacement Remove and dispose of existing equipment from premises Installation of Carrier 140k btu oil-fired boiler w/ tankless coil Installation of each boiler includes: 1- #60 expansion tank, 1- Watts autofeeder/backflow preventer, 1- mixing valve, 1- Spirovent air eliminator, 3- Grundfos Brute circulator pumps, 1- Taco SR5033 zone panel, 3- Honeywell T4 Pro thermostats, modification of exhaust piping to connect new boiler from existing chimney and new misc. copper piping and fittings to install new boiler. Boiler comes with new burner
01-11 0 009-18A ENGEL THOMAS P + VITALE KRISTEN 148 WOODBINE RD
25-311B
Building 08/20/2025 195.00 Approved Removal of the existing roofing shingles and installation of new underlayments and shingles (21 sq)
03-03 0 040-003 DWRE CONSTRUCTION LLC 76 RIDGEWOOD DR
25-313B
Building 08/20/2025 438.00 Approved Remove existing siding Install moisture barrier and tape Install lifetime vinyl siding and accessories
03-03 0 040-003 DWRE CONSTRUCTION LLC 76 RIDGEWOOD DR
25-312B
Building 08/20/2025 337.00 Approved Remove existing roofing install plywood seam tape 6 ft of ice and water synthetic felt lifetime architectural shingles and ridge vent
03-03 0 040-003 DWRE CONSTRUCTION LLC 76 RIDGEWOOD DR
25-131M
Mechanical 08/20/2025 195.00 Approved Boiler Replacement.8500
03-09 0 049-000 LAKE HAYWARD PROPERTIES LLC 91 LAKE HAYWARD RD
25-37P
Plumbing 08/20/2025 1431.00 Approved PVC drain waste & vent, Pex domestic hot and cold water piping, PVC radon piping, finish plumbing; Building 3
18-00 0 010-000 REIL SCOTT K + 48 ELMWOOD HGTS
25-130M
Mechanical 08/20/2025 175.00 Approved Install A New MST396ST Boiler (10 year warranty),
03-15 0 001-48A ALIGATA MARK S 83 STANDISH RD
25-310B
Building 08/19/2025 53.00 Approved replacing existing inoperable sliding patio door.
02-02 0 012-001 REID DENNIS + JENNIFER (S) 175 SCOTT HILL RD
25-27G
Fuel Gas 08/19/2025 33.00 Approved 1-120 gallon tank to stub
20-00 0 019-000 GAINES ROBERT + SANDRA J 135 BORETZ RD
25-128M
Mechanical 08/19/2025 357.00 Approved Installation of a new Mitsubishi 2-1 Ductless Heat Pump One new outdoor unit will be placed
06-10 0 082-01A CZECH JOSEPH S 24 SUNSET BLVD
Draft
Mechanical   641.00 Payment Due TO REPLACE EXISTING FIRST FLOOR ANDSECOND FLOOR HYDRO-AIR A/C SYSTEMS WITH NEW FIRST CO. AND LENNOX UNIT UNITS.
03-20 0 025-000 ROHON PATRICIA A 134 WATERHOLE RD
25-129M
Mechanical 08/19/2025 175.00 Approved installation of a medium flushwood wood insert, installed in a masonry fireplace with a 6" stainless steel liner kit per manufacturer specs
07-02 0 009-000 DELMASTRO JEFFREY R + 407 WINDHAM AVE
25-170E
Electrical 08/19/2025 53.00 Approved complete wiring of 2 zone gas boiler (installed by others)
01-11 0 009-43A PANCAROWICZ DAVID + CAROLYN 187 WOODBINE RD
25-169E
Electrical 08/19/2025 94.00 Approved Rough and final electrical of addition
03-07 0 036-014 CRUZ RANDY L + NANCY 52 CEDAR LN
25-172E
Electrical 08/20/2025 884.00 Approved Install (51) 440W Solar panels on the roof.
03-17 0 51A-000 715 MIDDLETOWN ROAD LLC 715 MIDDLETOWN RD
Draft
Electrical   33.00 Paid Relocate an existing light pole to new location
20-00 0 054-000 FORAN JOHN N 303 AMSTON RD
25-309B
Building 08/19/2025 519.00 Approved Remodel 5' x 8' existing first floor bathroom. Remove 32" x 60" tub and replace with 32" x 60" shower. Eliminate window from inside the existing tub area. Add bathroom exhaust fan/light.
4W-05 0 005-038 WB SHAW + ASSOCIATES LLC 48 VANCEDARFIELD RD
Draft
Driveway   50.00 Payment Due Driveway Construction
02-14 0 003-056 PETITTI KURT + KIMBERLY 55 ALFRED DR
Draft
Building   832.00 Paid Storage Garage 16'x32' built by Carefree Small Buildings - Colchester, CT Structure will sit on 6" of 3/4" stone
06-16 0 016-01A OPALENIK STEVEN D + MICHELE L 16 HILLSIDE LN
25-127M
Mechanical 08/19/2025 620.00 Approved INSTALLATION OF TWO MITSUBISHI MINI SPLIT SYSTEMS BOTH MODELS MXZ-3D30NLHZ WITH FIVE INDOOR UNITS ALL TOGETHER 3 MODELS MSZ-FX15NL, ONE MSZ-FX06NL AND ONE MSZ-FX09NL
02-08 0 039-000 BECKER JOANNE K + 181 MCDONALD RD
25-308B
Building 08/19/2025 478.00 Approved Remove old siding and install new siding. 14 squares of siding to be installed.
03-19 0 029-000 GAZDZICKI KIM E 773 MIDDLETOWN RD
25-307B
Building 08/19/2025 94.00 Approved Remove and replace one patio door, no structural changes. Like for like replacement.
06-12 0 045-019 HUYNH LE + RIOS MABEL 85 DEER RUN DR
25-171E
Electrical 08/20/2025 316.00 Approved Install (1) Tesla Energy Storage System (13.5 kwh)
09-00 0 002-000 COLCHESTER TOWN OF 300 OLD HARTFORD RD
Draft
Building   33.00 Paid Install a 31 x 19 hopper window in whole in concrete block wall between concessions and garage.
20-00 0 071-000 BROWN EHREN C 104 BORETZ RD
25-304B
Building 08/17/2025 418.00 Approved Remove existing shake siding and battens and dispose. Dumpster will be provided on site. Inspect existing sheathing and repair as needed. Install house wrap on entire surface being sided. Install Alside Odyssey 0.44 thickness, double 4" siding. Color to be decided. White outside corner posts, hidden vent soffit, light blocks, dryer vents, and split blocks included. All windows and doors will be capped with custom bent aluminum coil covering the j channel. Remove existing gutters and downspouts and install capping on all faccia and rake boards
05-06 0 018-000 0-05A ROBERTSON KAREN + FARRELL JORDAN 512 SPRINGBROOK CIR
25-306B
Building 08/19/2025 1127.00 Approved install a new shower conversion unit ( bathroom 1 ) and install a new tub ( bathroom 2 ) for replacement. no structural changes.
13-02 0 003-000 WILSON MARIA C 9 LAKEVIEW DR
Draft
Zoning   110.00 Paid shed replacement
06-08 0 009-000 PRESCOTT CINDY 486 OLD HARTFORD RD
25-106CA
COC 08/15/2025   Closed Roof mounted solar array of 20 panels @ 6.2kw/dc
05-12 0 001-007 RETTIG ADAM T 47 PROSPECT HILL RD
Draft
Building   690.00 Paid Post and beam pool house 24' x 28'
05-10 0 005-067 GOODEN WHITE CHRISMAE 162 MILL HILL RD
25-125M
Mechanical 08/14/2025 316.00 Approved Remove and replace the existing boiler in the exact same location and footprint as original with new Crown brand TWB100 boiler, flue pipe and controls.